Raul Refrigeration Basics Quiz September 1, 2022, 6:26 am

Leave a Reply

Your email address will not be published. Required fields are marked *

This site uses Akismet to reduce spam. Learn how your comment data is processed.

Related Tech Tips

Condenser Coil Cleaning Step by Step
The photo above is of a real condenser coil we cleaned. The outer fins looked OK, but dirt and lint were packed deep inside. We also had sky-high head pressure and condensing temperature; those are telltale signs of an impacted condenser. That situation illustrates that a coil can sometimes look OK at first glance but […]
Read more
Can A Motor Run Backwards by Swapping Run & Start?
Can a single-phase motor run backward when start and run are swapped? The answer is (generally) yes. Is the motor designed to run backward by simply swapping run and start? The answer is (generally) no, with a few notable exceptions. Before we jump in, this article has two purposes. #1 – it helps you understand […]
Read more
Shielded Control Cable & Communicating Controls
When I first started in the trade, we used to run into shielded control wires on the Carrier Comfort Zone 1 zoning systems and also on a Carrier VVT system I used to maintain at a bank. I knew it has something to do with electrical “noise” and that communicating systems often called for it, […]