Wiring and Setting of Humidistat/Dehumidistat in Humid Climates
If you live in a dry climate, a humidistat is pretty straightforward; it just turns a humidifier on and off. That's about as simple as it gets. If you are in a humid climate, some people have taken to wiring in humidistats as dehumidistats to help control humidity when they are away. The first thing […]
Read more
False Negatives on One Capacitor Test
I have spent the last few days checking run capacitors on various systems with several different meters, and this is what I found: #1 – Comparing Start wire amps against Run + Common under the clamp together is meaningless as a practical test. I used this test on 3 different systems with 3 different meters […]
Read more
Capacitor Testing and Replacement Procedure
  ❶ Understand What a Run Capacitor Does The run capacitor provides continuous phase-shifted current to the motor start winding, allowing the motor to run: With the design efficiency In the right direction With the appropriate torque With near “unity” power factor (power factor near 1.0) If the run capacitor is failed, the motor often […]