Relative Humidity in the Supply Air Stream
When you first start checking your supply air with a thermo-hygrometer, you may notice that the relative humidity is REALLY HIGH. Often, the RH in a supply duct will be between 85% and 96% relative humidity on a system that is functioning as designed. The reason for this is fairly simple: In order for dehumidification […]
Read more
A Critical Technician Trait in Decline
Our technician, Sam, sauntered into my office this afternoon like techs often do on a slow spring afternoon before the summer hits. It's been a long day for me, lots of training prep, a bunch of little fires, and errands to stomp out, and I still didn't get my article for the day written. I […]
Read more
Drains and Double traps
Double traps are no good. That's the end of this tech tip. Okay, here's some detail: Anytime your drain goes up and down more than once, you have a double trap UNLESS you place an air vent between the two traps that vents ABOVE the drain inlet. The double trap causes drainage issues because air […]