This article is a quick, real-life diagnosis/find by Kalos Services senior commercial HVAC/R tech Eric Mele. Improper Defrost Timer installation While servicing this display cooler for an unrelated problem, I noticed the defrost timer installed in a way that will almost certainly cause early compressor failure. Because this is a cooler (not a freezer), it […]
Read more
“What do you want to be when you grow up?” “Where will you go to college?” Young people hear those questions all the time. Although we ask those questions in good faith, they also carry a burden of expectations. By asking those questions, we imply that we expect the children to go to college […]
Read more
Suction Accumulators A suction accumulator is used to prevent liquid refrigerant floodback to the compressor. A compressor is designed to move vapor refrigerant, NOT liquid, and the accumulator can really help us win that battle. Accumulators are commonly used on heat pumps, transportation refrigeration systems, low-temp supermarket systems, and any place where liquid refrigerant flooding […]