Crankcase Heaters and Single-Pole Contactors
We keep two-pole, 40-amp 24v coil contactors on all of our vans. They are versatile and reliable, and you can replace most residential A/C contactors with them. There are a few things to watch for, though, especially when you have a crankcase heater. Many brands power the crankcase heater constantly and shut it on and […]
Read more
Unapologetically a Technician
For years, I've worked with and around people who view work, problems, and goals differently than I do. I've often told my wife that I have an issue managing and leading administrators, salespeople, and other inside staff. Why? It's because I just don't communicate in a way they seem to like. It's been 20 years […]
Read more
Ever Hear of Copper Plating Inside the Compressor?
First off, I want to thank Ulises Palacios for taking these photos. He is in the habit of cutting open the compressors he replaces to see why they failed (when possible). I think that's pretty boss. So, why would the compressor have copper plating on the inside? They certainly aren't manufactured that way. The short […]