Danfoss ERC213 Parameters Review
Danfoss ERC 213
Timestamps:
10:30 – Key Features
10:41 – Voltage Protection
10:56 – Compressor Protection
14:43 – Applications
15:15 – App 0 No predefined application
15:28 – App 1 Medium temperature ventilated refrigeration units with timed natural defrost
15:52 – App 2 Medium temperature ventilated refrigeration units with timed electrical defrost
16:03 – App 3 Low temperature ventilated refrigeration units with timed electrical defrost
16:13 – App 4 Medium temperature ventilated refrigeration units with electrical defrost (by temperature)
16:26 – App 5 Low temperature ventilated refrigeration units with electrical defrost (by temperature)
16:37 – App 6 No predefined application with simplified list of parameters
19:45 – Sensors
22:06 – Basic Groups of Parameters
23:09 – r– Thermostat
23:12 – r00 Temperature setpoint
23:24 – r01 Differential
23:32 – r02 Min setpoint limitation and r03 Max setpoint limitation
24:02 – r04 Display offset
25:19 – r05 Display Unit (°C/°F)
25:33 – r09 Calibration of Sair
25:47 – r12 Main switch
27:17 – r13 Night set back
27:48 – r40 Thermostat reference displacement (offset temperature)
28:30 – r96 Pull-down duration and r97 Pull-down limit temperature
29:06 – A– Alarms
29:13 – A03 Delay for temperature alarm during normal conditions
30:15 – A12 Delay for temperature alarm during pull-down/start-up/defrost
31:00 – A13 High temperature alarm limit (Cabinet/Room)
31:34 – A14 Low temperature alarm limit
31:55 – A27 DI1 delay and A28 DI2 delay
32:17 – A37 Condenser high alarm limit
32:41 – A54 Condenser high block limit
33:45 – A72 Voltage protection enable
34:03 – A73 Minimum cut-in voltage and A74 Minimum cut-out voltage
35:04 – A75 Maximum Voltage
37:37 – d– Defrost
37:49 – d01 Defrost method
38:32 – d02 Defrost stop temperature
38:50 – d10 Defrost stop sensor
40:51 – d03 Defrost interval
41:16 – d04 Max defrost time
43:38 – d05 Defrost delay at power up (or DI signal)
44:29 – d06 Drip delay
44:49 – d07 Fan delay after defrost
45:49 – d08 Fan start temperature after defrost
47:21 – d09 Fan during defrost
47:40 – d10 Defrost stop sensor (part II)
48:16 – d18 Compressor accumulated runtime to start defrost
50:04 – d19 Defrost on demand
53:26 – d30 Defrost delay after pull-down
53:53 – F– Fan control
54:03 – F01 Fan at compressor cutout
55:00 – F04 Fan stop evaporator temperature
55:51 – F07 Fan ON cycle and F08 Fan OFF cycle
56:28 – c– Compressor
56:37 – c01 Compressor minimum ON time
56:47 – c02 Compressor minimum OFF time
57:01 – c04 Compressor OFF delay at door open
57:51 – c70 Zero crossing selection
58:22 – o– Others
58:37 – o01 Delay of outputs at startup
59:11 – o02 DI1 configuration
1:01:36 – o05 Password
1:02:08 – o06 Sensor type selection
1:02:27 – 015 Display resolution
1:03:31 – o23 Relay 1 counter, o24 Relay 2 counter and 025 o24 Relay 3 counter
1:04:13 – o37 DI2 configuration
1:04:52 – o61 DI2 configuration
1:05:07 – o67 Save settings as factory
1:05:39 – o71 DO2 config
1:06:23 – o91 Display at defrost
1:07:04 – P– Polarity
1:07:06 – P73 DI1 input polarity and P74 DI2 input polarity
1:07:32 – P75 Invert alarm relay
1:07:59 – P76 Keyboard lock enable
1:08:21 – u– Readouts
1:08:30 – u00 Controller Status
1:09:37 – u01 Air temperature (Sair)
1:10:12 – u58 Compressor relay status, u59 Fan relay status, u60 Defrost relay status and u63 Light relay status