Does Air or Nitrogen Absorb Water?
There are many examples of teaching using metaphors to help someone grasp how something works without being EXACTLY correct. Some examples are how we often use water flow to explain electrical flow or refrigerant circuit dynamics. It's enough like the way it works to get our heads wrapped around it, but there are many differences. […]
Read more
Fan Blade Shroud Depth
When a system has abnormally high head pressure (high condensing temperature over ambient) and compression ratio, one of the easiest things to look for is a dirty condenser coil. More often than not, that will be the cause. However… There is another category of issues that can cause high condensing temperature (high head pressure), but these […]
Read more
The "5 Pillars" of Residential A/C Refrigerant Circuit Diagnosis
Suction pressure, head pressure, subcooling, superheat, delta T. Taking all five of these calculations into account on every service call is critical. Even if you must do further diagnostic tests to pinpoint the problem, these five factors are the groundwork before more effective diagnostics can be done. I would also add static pressure as an […]